Initial checks
Log Directory
No Log File Is Created
A Monitoring Rule Does Not Appear
Overview
Use this guide to diagnose installation, startup, configuration, Windows UI monitoring, data-upload, and .NET Profiler issues affecting the GermainUX Agent.Initial checks
For most problems, start by confirming:- The Agent is running with administrator privileges.
- The correct monitoring rule is applied.
- The target application has been restarted since the configuration changed.
- The GermainUX server is reachable.
- Logging is enabled for the affected component.
Component Logs
The GermainUX Agent, Windows UI worker, and .NET Code Profiler use independent log levels.INFO by default. Windows UI worker and CLR Profiler logging are disabled by default because each monitored process can generate a separate log.
Enable DEBUG or TRACE only while investigating a problem. Return the setting to its previous value after troubleshooting to avoid unnecessary disk usage.
For Registry configuration details, see GermainUX Agent Settings.
Log Directory
All components write to the directory defined by the machine-wideLogPath Registry value.
Default:
%LOCALAPPDATA% is user-specific, the actual directory depends on the Windows account running each process.
Logs use rotation with:
Log Files
Apply Logging Changes
Registry settings are read when a component starts. After changing a log level:- Restart
GermainUXAgent.exeto applyAgentLogLevel. - Restart the target application to create a new Windows UI worker and apply
WorkerLogLevel. - Restart the target .NET application to reattach the profiler and apply
CLRLogLevel.
No Log File Is Created
If a component is configured with a log level other thanOFF, but no corresponding file appears, verify that its process identity can write to LogPath.
Logging failures are designed not to crash the component. Therefore, a missing log file can indicate that:
- The directory does not exist.
- The directory is not writable.
- The target application uses a different Windows account from the Agent.
- Endpoint security software is blocking file creation.
- The component did not start or attach successfully.
“GermainUX Agent Must Be Run as Administrator”
The Agent requires elevated privileges to detect processes starting and stopping on the computer. It checks its privileges during startup and exits if it is not elevated.When Starting the Agent Manually
Right-clickGermainUXAgent.exe and select:
Run as administrator
When the Error Occurs After Login
The 64-bit installer creates a scheduled task that starts the Agent when a user logs in and requests the highest privileges available to that user. If the logged-in user is a local administrator, the Agent starts elevated without displaying a UAC prompt. If the user is not a local administrator, the scheduled task cannot provide the required elevation and the Agent exits. Make sure the Windows account that remains logged in on the monitored computer is a local administrator. For details, see GermainUX Agent Installation.No Data Appears in GermainUX
Complete the following checks in order.1 1. Confirm That the Agent Is Running
Verify that:- The GermainUX Agent icon appears in the Windows system tray.
GermainUXAgent.exeis running.germain-agent.logcontains a successful startup message.- The process is running with elevated privileges.
2. Confirm the GermainUX Server URL
Check the following Registry value:- The URL is present.
- It uses the correct protocol, normally
https://. - It references the correct GermainUX environment.
- It does not contain an unintended path or typographical error.
3. Check the Environment Filter
Review theEnvironment Registry value.
If it contains an environment name such as:
prod would not be applied.
Leave Environment empty to accept monitoring rules from every environment.
4. Confirm That Monitoring Is Enabled
Right-click the Agent tray icon and verify that Monitoring Enabled is selected. If monitoring was paused, the Agent can continue running without collecting data.5. Refresh the Configuration
Right-click the tray icon and select Refresh Config. This forces the Agent to retrieve the latest rules instead of waiting for the nextPollInterval.
Review germain-agent.log for errors if the refresh fails.
6. Confirm That a Rule Matches the Application
Open the tray icon’s Configurations submenu. Verify that the target application appears and that:- The executable name is correct.
- The rule is enabled.
- Windows UI monitoring is enabled when required.
- CLR attachment is enabled for .NET diagnostics.
- The rule belongs to the correct environment.
- The displayed configuration is the expected local or server-provided rule.
- Confirm that a server-provided rule targets its exact executable name.
- For a local rule, verify the Registry subkey:
HKEY_LOCAL_MACHINE\SOFTWARE\Germain Software\Germain Agent\Targets\{executableName.exe} - Confirm that the executable name includes
.exe. - Confirm that
ConfigFilecontains a valid absolute path. - Confirm that
Enabledis set to1.
7. Restart the Target Application
The Agent normally starts a new Windows UI worker and attaches the CLR Profiler when it detects a new target process. After changing a rule:Close the target application completely
Confirm that its process has exited
Start the application again
Check whether a Windows UI worker starts
Review the applicable worker or profiler log
8. Check Server and Network Connectivity
Confirm that the monitored computer can reach the configured GermainUX URL. Check for:- Firewall restrictions
- Proxy requirements
- DNS failures
- TLS or certificate problems
- Authentication failures
- Blocked outbound HTTPS
- Network security products terminating the connection
germain-agent.log.
Data-upload failures appear in the relevant:
- Windows UI worker log
- CLR Profiler log
9. Check queue.outputPath
Inspect the resolved rule JSON from the Configurations submenu.
If queue.outputPath contains a file path, facts are written to that local file instead of being sent to GermainUX.
For normal server delivery, leave it empty:
10. Review Privacy and Exclusion Rules
If only certain values or facts are missing, inspect:maskAllexclusions- Feature-level inclusion and exclusion patterns
- HTTP request and response body exclusions
- Control selectors
A Monitoring Rule Does Not Appear
If the expected rule is missing from Configurations:Select Refresh Config
Review germain-agent.log for server-polling errors
Verify the Agent’s Environment value
Confirm that the server-side rule targets the exact executable filename
For a local rule, confirm the Targets\{executableName.exe} Registry key
Confirm that the JSON configuration file exists and is readable
Validate the JSON syntax
Restart the Agent
Windows UI Monitoring or Replay Does Not Start
If application-level information is present but Windows UI interactions or replay are missing:- Confirm that the rule enables the Windows UI worker.
- For a local rule, verify:
UiaWorkerEnabled = 1 - Confirm that
features.monitor.enabledistrue. - Confirm that the required subfeature is enabled, such as:
userClicksuserSearchesclickMapsmouseMapsuserFacingErrorsreplay
- Restart the target application.
- Enable
WorkerLogLevelatDEBUG. - Review the target’s
germain-uia-worker-{ruleName-}{pid}.log. - Confirm that
GermainUXRumWindows.exeremains in the same installation directory asGermainUXAgent.exe.
Interactions Are Missing but Replay Works
If only specific clicks or searches are missing:- Check the UI Automation control type.
- Confirm the control’s
AutomationId. - Confirm its visible label.
- Confirm its Win32 class name.
- Review configured regular expressions.
- Verify whether a selector requires a double-click.
- Confirm that all specified filter fields match; filter conditions use AND logic.
Replay Is Incomplete or Drifts from the UI
If replay does not accurately reflect the application:Confirm that the required replay events are enabled
Review thumbnail rules
Review color-sampling configuration
Temporarily enable the relevant debug options while working with Germain Software Support
Consider selfHealEnabled only when actual replay drift has been confirmed
Installer Reports a Missing Redistributable
The MSI installer requires Microsoft Visual C++ 2015–2022 Redistributable. Install the package matching the installer architecture:.NET Profiler Does Not Attach
If .NET metrics, exceptions, garbage-collection facts, or CPU samples are missing, verify the following.Confirm CLR Attachment Is Enabled
For a local rule, verify:Confirm the Target Is a .NET Process
Run:- Classic .NET Framework
- Modern .NET Core or .NET 5 and later
Confirm the Application Architecture
A profiler DLL must match the target process architecture:Confirm the Profiler DLL Location
The profiler DLL must remain in its installed directory with the related Agent components. Do not move or rename it independently..NET Profiler Attachment Fails Without Creating a Log
Typical symptoms include:- No
germain-clr-agent-{pid}.logfile is created. CLRLogLevelis set to a value other thanOFF.germain-agent.log, atDEBUGorTRACE, reports an attachment failure such as “Catastrophic failure.”
LogPath.
The Agent may run as an elevated administrator while the target application runs as another, less-privileged account.
To resolve the issue:
Identify the account running the target application
Verify that it has write access to LogPath
If necessary, configure LogPath to use a directory writable by every monitored account
Restart the Agent
Restart the target application
Check whether a new profiler log appears
Use AgentConsole.exe
AgentConsole.exe is a standalone diagnostic utility installed with the GermainUX Agent and Code Profiler packages.
It helps verify what Windows and the CLR expose before investigating Agent-specific behavior.
List Processes With a Loaded CLR
Run from an elevated Command Prompt:- Processes with a loaded CLR
- Process IDs
- Whether the process uses classic .NET Framework
- Whether it uses .NET Core, .NET 5, or a later runtime
- That the target is a .NET process
- That the CLR is loaded
- Which profiler attachment mechanism applies
- Which process ID should have a corresponding CLR log
Display Available Commands
--help to obtain the command list available in the installed build.
Information to Collect for Germain Software Support
If the issue remains unresolved, collect:- GermainUX Agent version
- Windows version and architecture
- Target application name, version, executable name, and architecture
- Target runtime, such as Win32, WPF, Windows Forms, .NET Framework, or modern .NET
- Whether the rule is local or server-provided
- The resolved JSON shown under Configurations
Show all 16
Show all 16
- Relevant Registry settings
germain-agent.log- Applicable Windows UI worker log
- Applicable CLR Profiler log
- Target process ID
- Output from
AgentConsole.exe --list, when relevant - Approximate problem time and timezone
- Steps required to reproduce the issue
- Whether the issue affects every user or device
- Any recent application, Agent, network, proxy, or security-policy change
Related Documentation
- GermainUX Agent Installation
- GermainUX Agent Settings
- Monitoring Configuration Reference
- Windows Application Monitoring KPIs
Get Help
Contact GermainUX Support
Can't find what you need?
The content of this document is proprietary to GERMAIN SOFTWARE LLC.