# Change Log Levels for Oracle Siebel CRM

> Raise the event log level of Siebel components for a set time to capture evidence for an incident, and let GermainUX turn it back down automatically.

Components
[`Engine`](https://docs.germainux.com/deploy/germain-ux-engine)

Availability
2026.2 or later

> [card] [How It Works](#how-it-works)
>
> Change and revert jobs

> [card] [Before You Start](#before-you-start)
>
> Access and names

> [card] [Set It Up](#set-it-up)
>
> Run the wizard

> [card] [Troubleshooting](#troubleshooting)
>
> Fix failed changes

## Overview

When you investigate a Siebel incident, the Object Manager logs often don't hold enough detail at the normal log level. The **Siebel Log Level** wizard raises the event log level of the Siebel components you choose, and then turns it back down at the time you set. You capture the evidence you need, and the components don't stay on verbose logging after the incident.

Choose Components
Raise the Level
Collect Evidence
Automatic Revert

For the crashes and errors you collect the evidence for, see [Error Monitoring for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/siebel-error-monitoring-configuration.md) and [Crash Monitoring for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/siebel-crash-monitoring-configuration.md).

## How It Works

The wizard creates two jobs on the Engine of the node you choose:

| Job | When it runs | What it does |
| - | - | - |
| **Change** | As soon as you submit the wizard | Sets each component's event log level to the level you chose |
| **Revert** | At the **Revert At** time | Sets each component's event log level to its revert level |

Each job runs the Siebel Server Manager (`srvrmgr`) with one `change evtloglvl` command per component, for example `change evtloglvl %=5 for component CallCenter_enu`. It runs once for each server you select, or once for the whole Siebel Enterprise when you don't select a server. The revert job runs even when the change job didn't fully succeed.

## Before You Start

* A GermainUX Engine that can run `srvrmgr`, either on its own host or over SSH on a Siebel server. See [Engine Deployment for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/engine-deployment-for-oracle-siebel-crm.md).
* Stored credentials for a Siebel administrator account that can change log levels with `srvrmgr`.
* For SSH, the Siebel server added as a server in GermainUX, and stored SSH credentials for it.
* The Siebel Gateway host and port, and the Siebel Enterprise name.
* The aliases of the components to change, such as `CallCenter_enu`.
* Enough free disk space on the Siebel servers for the larger logs that a higher level writes.

## Set It Up

**1. Open the wizard**

In the left menu, go to **Settings > Wizards**. Next to **Show**, click **Actions**. On the **Siebel Log Level** card, click **Add**.

**2. Choose where srvrmgr runs**

On the **Execution** step, fill in the fields, and then click **Next**:

| Field | Value |
| - | - |
| **Execution Node** | The monitoring node whose Engine runs the jobs |
| **Connection Mode** | **Local** runs `srvrmgr` on the Engine host. **SSH** runs it on a Siebel server over SSH. |
| **Remote Host** | For **SSH** only. The Siebel server to connect to. |
| **SSH Credentials** | For **SSH** only. The stored credentials for the SSH connection. |
| **Remote Port** | For **SSH** only. The SSH port. The default is `22`. |

**3. Choose the servers**

On the **Servers** step, under **Servers**, select the Siebel servers to change. To change the components on every server in the Siebel Enterprise, leave **Servers** empty.

When you leave **Servers** empty, you can select a server under **Copy Connection Properties From** to fill in the next step from it. Click **Next**.

All the servers you select must belong to the same Siebel Enterprise.

**4. Enter the Siebel connection**

On the **Connection** step, fill in the fields, and then click **Next**. GermainUX fills them in from the first server you selected, when that server has the values stored.

| Field | Value |
| - | - |
| **Gateway** | The Siebel Gateway, as `hostname:port`. `srvrmgr` connects to it with `/g`. |
| **Enterprise** | The Siebel Enterprise name. `srvrmgr` connects to it with `/e`. |
| **Credentials** | The stored credentials of the Siebel administrator account. `srvrmgr` logs in with them (`/u` and `/p`). |
| **Siebel Path** | The Siebel Server installation directory, which contains the `bin` directory with `srvrmgr` |

**5. Choose the components and levels**

On the **Components** step, add a row for each component and event type to change:

| Field | Value |
| - | - |
| **Component Name** | The component alias, such as `CallCenter_enu`. Use letters, digits and underscores only. |
| **Event Name** | The event type to change, such as `ObjMgrSqlLog`. Leave it empty, or enter `%`, to change every event type of the component. |
| **Level** | The new log level, from `1` to `5` |

![Components step of the Siebel Log Level wizard, with rows for the component name, event name and level](https://mintcdn.com/germain-ux/_4CUtmzVeT3f0E47/images/main/siebel-log-level-configuration/components-step.png?fit=max\&auto=format\&n=_4CUtmzVeT3f0E47\&q=85\&s=0bf45c9d27eff8c7357a5881f6d763f8)

Siebel Log Level Wizard, Components Step - GermainUX

Click **Next**.

**6. Set the revert**

On the **Revert** step, under **Revert At**, choose when GermainUX turns the logging back down. Then, for each component, choose the **Revert Level**, usually the level it had before. Click **Next**.

![Revert step of the Siebel Log Level wizard, with the Revert At date and time and a revert level for each component](https://mintcdn.com/germain-ux/_4CUtmzVeT3f0E47/images/main/siebel-log-level-configuration/revert-step.png?fit=max\&auto=format\&n=_4CUtmzVeT3f0E47\&q=85\&s=c67ddb834315e7c3f61b2dc3f80871fb)

Siebel Log Level Wizard, Revert Step - GermainUX

**7. Review and submit**

On the **Review** step, check the servers, the connection and each component's change and revert levels, and then click **Submit**.

Siebel event log levels go from `1`, the least detail, to `5`, the most:

| Level | What Siebel logs |
| - | - |
| `1` | Errors |
| `2` | Warnings |
| `3` | Informational messages |
| `4` | Detailed messages |
| `5` | Diagnostic messages |

> [!WARNING]
>
> Levels `4` and `5` can make the logs grow quickly and slow the component down. Raise only the components and event types you need, and set **Revert At** to the end of the time you need to capture.

## Validate

**1. Check the jobs**

In the left menu, go to **Settings > Germain > Jobs**. The change job shows a result for each server and component. The revert job waits for the **Revert At** time.

**2. Check the level in Siebel**

Run `list evtloglvl for component <alias>` in `srvrmgr`, for example `list evtloglvl for component CallCenter_enu`, and check the level of the event types you changed.

**3. Check the revert**

After the **Revert At** time, check the revert job in **Settings > Germain > Jobs**, and run `list evtloglvl` again.

## Troubleshooting

> [accordion] The servers step says the servers must belong to the same Siebel Enterprise
>
> The selected servers have different Gateway, Enterprise, Siebel Path or credentials values. Run the wizard once for each Siebel Enterprise.

> [accordion] The change job fails for every server
>
> Check the job output in **Settings > Germain > Jobs**. Make sure that the **Siebel Path** contains `bin/srvrmgr` (`bin\srvrmgr.exe` on Windows), that the **Gateway** and **Enterprise** are correct, and that the Siebel account can log in to `srvrmgr`. For **SSH**, also check the SSH credentials and port.

> [accordion] The change job fails for one server only
>
> Check the job output for that server in **Settings > Germain > Jobs**, and check that the Siebel server was running when the job ran.

> [accordion] The level wasn't reverted
>
> The Engine of the execution node must be running at the **Revert At** time. If it wasn't, run the wizard again with the revert levels as the new levels, or change them in `srvrmgr`.

## Security and Privacy

A higher log level makes Siebel write more detail to its logs, and the GermainUX parsers read those logs. The extra detail includes Siebel user names, SQL statements and other free text. Treat it as possibly containing personal or customer data.

The job results in **Settings > Germain > Jobs** include the `srvrmgr` output for each server.

To mask, anonymize or exclude this data, see [Data Privacy](https://docs.germainux.com/management/compliance-privacy-and-security/data-privacy.md).

## Related Documentation

> [card] [Error Monitoring for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/siebel-error-monitoring-configuration.md)
>
> Object Manager and browser errors

> [card] [Crash Monitoring for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/siebel-crash-monitoring-configuration.md)
>
> Crashes, FDR and core files

> [card] [Application Monitoring for Oracle Siebel CRM](https://docs.germainux.com/integrations/oracle-siebel-crm/siebel-application-monitoring-configuration.md)
>
> Siebel server wizards

## Get Help

> [card] [Contact GermainUX Support](https://docs.germainux.com/getting-started/support.md)
>
> The GermainUX team helps you get up and running faster, empower your team, turn data into actionable insights, and optimize performance to deliver measurable business outcomes.

> [card] Can't Find What You Need?
>
> Search all GermainUX docs with **Ctrl + K**, or use the feedback buttons at the bottom of this page to tell us what is missing.

The content of this document is proprietary to GERMAIN SOFTWARE.


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.